AMBIENTUM BIOETHICA BIOLOGIA CHEMIA DIGITALIA DRAMATICA EDUCATIO ARTIS GYMNAST. ENGINEERING EPHEMERIDES EUROPAEA GEOGRAPHIA GEOLOGIA HISTORIA HISTORIA ARTIUM INFORMATICA IURISPRUDENTIA MATHEMATICA MUSICA NEGOTIA OECONOMICA PHILOLOGIA PHILOSOPHIA PHYSICA POLITICA PSYCHOLOGIA-PAEDAGOGIA SOCIOLOGIA THEOLOGIA CATHOLICA THEOLOGIA CATHOLICA LATIN THEOLOGIA GR.-CATH. VARAD THEOLOGIA ORTHODOXA THEOLOGIA REF. TRANSYLVAN
|
|||||||
The STUDIA UNIVERSITATIS BABEŞ-BOLYAI issue article summary The summary of the selected article appears at the bottom of the page. In order to get back to the contents of the issue this article belongs to you have to access the link from the title. In order to see all the articles of the archive which have as author/co-author one of the authors mentioned below, you have to access the link from the author's name. |
|||||||
STUDIA CHEMIA - Issue no. 3 / 2019 | |||||||
Article: |
PRE-COATED MERCURY FILM ON GLASSY-CARBON ELECTRODE FOR THE SIMULTANEOUS DETERMINATION OF Cu2+, Zn2+, Cd2+, AND Pb2+ IN WATER. Authors: JINGXUAN PEI, XIANG YU, XINGJU LIU, CHAO ZHANG. |
||||||
Abstract:
A mercury film was pre-coated on glassy-carbon electrodes to improve the precision and detection limit of the electrodes in anodic stripping voltammetry. A mixed solution containing 0.1 mg/l Zn2+ , 0.01 mg/l Pb2+ , 0.01 mg/l Cd2+ , and 0.5 mg/l Cu2+ was used to investigate the simultaneous detection of these ions by the electrode. The influence of the base solution pH and the accumulation time on the electrochemical reactions of Cu2+ , Zn2+ , Cd2+ , and Pb2+ were investigated, as well as the effect of the concentration of the film coating solution and the number of mercury coating step on the stripping signals of the four ions. Optimizing the parameters of the pre-coated mercury film improved the precision of the glassy-carbon electrode in evidence. When the base solution pH was 4.68, and the accumulation time was 300 s, the positions of the stripping peaks were optimal, and the peak signals were at a maximum. When the concentration of the film coating solution was 0.03 mol/l HgCl2, and the mercury coating step was repeated three times, the prepared electrode showed a moderately high elution peak with little noise. The optimized electrode demonstrated superior precision and detection limits in the simultaneous detection of Zn2+ , Cd2+ , Pb2+ , and Cu2+ , compared with the uncoated electrode. The calibration curves were highly linear with determination coefficients (R2) of 0.9913 (Cu2+ ), 0.9939 (Pb2+ ), 0.9933 (Cd2+), and 0.9962 (Zn2+); the detection limits (µg/l) were 5 for Cu2+ , 1 for Pb2+ , 0.1 for Cd2+ , and 10 for Zn2+ , and the relative standard deviations obtained from five replicate experiments were 4.1% (Cu2+ ), 2.1% (Pb2+ ), 2.7% (Cd2+ ), and 3.4% (Zn2+ ). It is reasonable to suppose that the precision and detection limits of this mercury film electrode may meet the requirements for the simultaneous detection of multiple heavy metal ions in water in the natural environment. Keywords: Glassy-Carbon Electrode, Mercury Film, Heavy Metal Ions, Anodic Stripping Voltammetry
|
|||||||