AMBIENTUM BIOETHICA BIOLOGIA CHEMIA DIGITALIA DRAMATICA EDUCATIO ARTIS GYMNAST. ENGINEERING EPHEMERIDES EUROPAEA GEOGRAPHIA GEOLOGIA HISTORIA HISTORIA ARTIUM INFORMATICA IURISPRUDENTIA MATHEMATICA MUSICA NEGOTIA OECONOMICA PHILOLOGIA PHILOSOPHIA PHYSICA POLITICA PSYCHOLOGIA-PAEDAGOGIA SOCIOLOGIA THEOLOGIA CATHOLICA THEOLOGIA CATHOLICA LATIN THEOLOGIA GR.-CATH. VARAD THEOLOGIA ORTHODOXA THEOLOGIA REF. TRANSYLVAN
|
|||||||
The STUDIA UNIVERSITATIS BABEŞ-BOLYAI issue article summary The summary of the selected article appears at the bottom of the page. In order to get back to the contents of the issue this article belongs to you have to access the link from the title. In order to see all the articles of the archive which have as author/co-author one of the authors mentioned below, you have to access the link from the author's name. |
|||||||
STUDIA CHEMIA - Issue no. 1 / 2022 | |||||||
Article: |
TESTING OF NEW EXPERIMENTAL GIOMERS: WATER SORPTION, CONVERSION DEGREE, RADIOPACITY, MICROSTRUCTURE AND BIOLOGICAL BEHAVIOR. Authors: SANDA ILEANA CIMPEAN, IOANA AMBROSIE, MĂDĂLINA MOLDOVAN, ADA DELEAN, DOINA PRODAN, CRISTINA PREJMEREAN, MARIOARA MOLDOVAN, MARIA TOMOAIA-COTISEL, LOREDANA COLCERIU-BURTEA. |
||||||
Abstract: DOI: 10.24193/subbchem.2022.1.12 Published Online: 2021-03-15 Published Print: 2021-03-30 pp. 177-194 VIEW PDF FULL PDF Two experimental giomers (G1 and G2) were obtained and then evaluated for water sorption- by weighing the specimens before and after water immersion, for conversion degree (DC)- by Fourier Transform Infrared Spectrometry, for radiopacity- by using the intraoral sensor system Ez Sensor 1.5 Vatech E-Woo (Korea), in relation to their microstructural characteristics assessed by Scanning Electron Microscopy (SEM). They were compared to a commercial giomer: Beautifil II. Both experimental and commercial giomers were also tested by subcutaneous and intramuscular implantation tests, to establish and compare their biological behavior. Intensity of the inflammatory reaction, tissue repair status and the presence of the capsule were the main criteria assessed. After 7 days, the mean values of DC were: 65.8% (Beautifil II), 62.2% (G2) and 60.5 (G1). DC increased after the initial polymerization. Giomers showed mean values of water sorption, below 40 µg/mm3. A certain swelling of the polymer matrix without dislocations of particles could be seen on SEM images. The mean values of radiopacity were between 2.15-2.99 [mmAl]. Giomers were slight to moderate irritants for soft tissues, with no significant difference between the samples. Promising results make G1 and G2 possible alternative to Beautifil II, that can be further improved. Keywords: giomer, conversion, water sorption, radiopacity, SEM, biocompatibility |
|||||||